Welcome to visitQingdao Lehler Filtering Technology Co.,Ltd.,Service hotline:+86-13335049999
Products

PRODUCT list

产品分类

news

新闻动态

CONTACT US

联系我们

    Qingdao Lehler Filtering Technology Co.,Ltd.

    Contact: Mr. Mark

    H/P: +86-15864745888

    Tel: +86-532-87117999

    Fax: +86-532-87151555

    E-mail: info@lehler.com

    Address: No.358, Feiyu Road, Huangdao District, Qingdao City, Shandong Province, China.

    Zip code: 266400



Products
Current location:Home > Products > Auto Self-cleaning Filter > Pneumatic Self-cleaning Filter
Pneumatic self-cleaning filter LFA-D219
Detailed introduction

Specification: 
■ Model: LFA-D219

■ Filtration surface area: 0.18㎡

■ Filter element: Wedge wire screen (v-slot screen)

■ Filtration rate: 0.15mm (minimum 20microns).

■ Housing material: SS304/ SS316L/ 2205/ 2507…

■ Filter element material: SS304/ SS316L/ 2205/ 2507…

■ Inlet: DN40

■ Outlet: DN40

■ Design pressure: 1.0 MPA

■ Design temperature: 0-200 ℃

■ Drain outlet: DN32

■ Housing material: SS304

■ Filter element material: SS304 

■ Scraper material: PTFE  

■ Pneumatic cylinder: AirTAC

■ Power control box: Explosion proof

■ Blowdown valve: pneumatic ball valve

■ Filter surface treatment: Electric polish/ Sand-blasting/ Painting

 

Applicable industry:

Food & Beverage/ Fine Chemical/ Petrochemical/ Pharmaceutical/ Cosmetic/ Mineral/ Pulp&Paper/ Waste water Treatment

 

Working principle:

The raw liquid enters the filter through the inlet. During the filtration process, the impurity is accumulated on the stainless steel wedge wire filter element, and the inner impurity is gradually accumulated.

1. Automatic cleaning: When filtration working time reaches the set point, the electronic control system signal will work. The cylinder begins to work; the cylinder drives the PTFE scraper up and down to remove the particles on the filter element internal surface. When cleaning time reaches the set point, the drain valve is opened to blow down.

2. Manual cleaning: The cylinder drives the PTFE scraper to move up and down to remove the particles on the filter element internal surface continuously. When the time reaches the set point, the drain valve opens and starts to blow down.

3. Pressure difference cleaning (optional): When pressure difference between the inlet and the outlet reaches the set point, the cylinder starts to work. The cylinder drives the PTFE scraper to move up and down to removes impurities on the filter element. When the cleaning time reaches the set point, cylinder stops working.

Back to list

Contacts:Mr. Mark

Telephone:15864745888

Address: No.358, Feiyu Road,Huangdao District, Qingdao City,Shandong Province, China.

Code scanning
CopyRight © 2020. Qingdao Lehler Filtration Technology Co., Ltd All Rights Reserved. 鲁ICP备19047118号-1
Support: shangzhixin
-->

Auto Self-cleaning Filter

Return
Pneumatic self-cleaning filter LFA-D219
Detailed introduction

Specification: 
■ Model: LFA-D219

■ Filtration surface area: 0.18㎡

■ Filter element: Wedge wire screen (v-slot screen)

■ Filtration rate: 0.15mm (minimum 20microns).

■ Housing material: SS304/ SS316L/ 2205/ 2507…

■ Filter element material: SS304/ SS316L/ 2205/ 2507…

■ Inlet: DN40

■ Outlet: DN40

■ Design pressure: 1.0 MPA

■ Design temperature: 0-200 ℃

■ Drain outlet: DN32

■ Housing material: SS304

■ Filter element material: SS304 

■ Scraper material: PTFE  

■ Pneumatic cylinder: AirTAC

■ Power control box: Explosion proof

■ Blowdown valve: pneumatic ball valve

■ Filter surface treatment: Electric polish/ Sand-blasting/ Painting

 

Applicable industry:

Food & Beverage/ Fine Chemical/ Petrochemical/ Pharmaceutical/ Cosmetic/ Mineral/ Pulp&Paper/ Waste water Treatment

 

Working principle:

The raw liquid enters the filter through the inlet. During the filtration process, the impurity is accumulated on the stainless steel wedge wire filter element, and the inner impurity is gradually accumulated.

1. Automatic cleaning: When filtration working time reaches the set point, the electronic control system signal will work. The cylinder begins to work; the cylinder drives the PTFE scraper up and down to remove the particles on the filter element internal surface. When cleaning time reaches the set point, the drain valve is opened to blow down.

2. Manual cleaning: The cylinder drives the PTFE scraper to move up and down to remove the particles on the filter element internal surface continuously. When the time reaches the set point, the drain valve opens and starts to blow down.

3. Pressure difference cleaning (optional): When pressure difference between the inlet and the outlet reaches the set point, the cylinder starts to work. The cylinder drives the PTFE scraper to move up and down to removes impurities on the filter element. When the cleaning time reaches the set point, cylinder stops working.

Previous:Pneumatic self-cleaning filter LFA-D450

Next:Pneumatic self-cleaning filter LFA-D273

Back to list